Toll Free: (877) 625-2309 
954) 636-9960 
Fax: (954) 388-1008 
WE ACCEPT PURCHASE ORDERS
Home Contact About Terms & Shipping Get Quote
Audiometers
Blood Drawing Chairs
Blood Pressure Mointors
Cold Therapy
Cryosurgery
Dental Instruments
Dermatoscopes
Disposables
Dopplers
Hampers
Headlights
IV Stands
Laboratory Equipment
and Supplies
Lighting
Loupes
Medical Chart Carts
Medical Recliners
Narcotics Cabinets
Ophthalmoscopes
Orthopedic Equipment
& Casting Material
Otoscopes
Prescription Vials
and Containers
Physical Therapy
Evaluation Products
Privacy Screens
Research Products
Spirometers
Stainless Steelware
Sterile Procedure Trays
Sterilizers
Stools
Surgical Instruments
Sutures
Tourniquets and Cuffs
Treatment Tables
Utility Carts
Vein Transilluminators
Veterinary Products
Vision Testing
Equipment
Wall Desks
Xray



We accept
All Major Credit Cards
You do NOT need a Paypal Account to Order

We accept purchase orders from hospitals, research facilities, government institutions, and qualified businesses.
 
Audiometers

Audiometer Model 650AB

AMBCO 650 Audiometers
Pure Tone Audiometers
FEATURES
  • Portable, light weight
  • Easy to use tone switch
  • Tone present indicator
  • Plug-in 110 or 220 volt, 650A
  • Plug-in and battery, 650AB
  • Battery life indicator
  • Five year warranty
  • Extremely accurate
  • Exceeds all specifications
  • Steady and pulsed tone
  • Custom carrying bag
  • Patient response
  • 5 YEAR LIMITED WARRANTY
SPECIFICATIONS
  • Meets or exceeds ANSI S3.6 1989, (ASA 81-1989) ISO 389-1985, C.H.D.P, O.S.H.A, E.P.S.D.T. F.A.A., Police, Divers, requirements.
  • Frequency Range: 250, 500, 1000, 2000, 3000, 4000, 6000, 8000 Hz Accuracy better than � 3%, (steady and pulsed tone)
  • Hearing Threshold Range: 0 to 90dB in 5dB steps Accuracy better than � 2 dB
  • Harmonic Distortion - less than 3%
  • Power: 110-230 VAC, 50-60 HZ UL, C.S.A. approved power supply. Long hour operation on one 9 volt battery (650AB).
  • Total Weight less than 4.5 Ibs (complete with headset, TDH 39 earphones, patient response, audiogram pad and carrying bag.)
650A AMBCO Manual Audiometer (AC Adapter) $927.00 Call to Order
650AB AMBCO Manual Audiometer (AC Adapter and Battery) $950.00 Call to Order


Model 1000
1000 + OTO-SCREEN




Model 1000P
1000 + OTO-SCREEN

AMBCO Digital Audiometer 1000 + OTO-SCREEN
THE INDUSTRY'S NEWEST AND ONLY PURE TONE AUDIOMETER

WITH SEQUENTIAL SCREENING The Model 1000 + OTO-SCREEN is a standard threshold & screening audiometer with the option of sequential testing.
By the push of a button the sequential mode allows the operator to select the screening dB (Threshold). (10-35 dB in 5dB steps).
Sequential screening is conducted at the school testing frequencies, 1000, 2000, 4000 Hz or the medical screening at 1000, 2000, 3000, 4000 Hz.
The screening starts with a 40 dB familiarization tone.
A positive response by the patient with the patient response switch initiates the sequential test tones presented at 1000 Hz, 2000 Hz, 3000 Hz, and 4000 Hz to each ear.
Sequential testing proceeds only after each timely response.
If there is no response of a false response the fail light alerts the operator.
Tones are presented at random to eliminate second guessing.
Timely responses advance to the nest frequency until both ears are tested.
A pass light indicates to the operator the test was completed successfully.
The operator is in control and can select standard threshold or screening mode by the push of a button.

FEATURES
  • Unique instrument advances pure tone air conduction threshold and screening tests for hearing.
  • The Model 1000 + OTO-SCREEN is a standard threshold & screening audiometer with the option of sequential testing.
  • Sequential screening eliminating fatigue factor.
  • OTO-SCREEN is microprocessor controlled resulting in accurate, consistent hearing tests.
  • Hands-off screening gives the operator complete control of testing procedure.
  • 5 YEAR LIMITED WARRANTY
SPECIFICATIONS:
  • Meets or exceeds ANSI 3:6 - 1996. ANSI 3.21 1978 (R 1997) Methods for pure-tone threshold audiometry.
  • O.S.H.A. C.H.D.P. and other requirements
  • Standard Mode - dB (Threshold Level) 0 to 90dB in 5dB steps. Frequency Range: 250, 500, 1000, 2000, 3000, 4000, 6000, 8000 Hz.
  • OTO-SCREEN Mode - dB (Threshold Level) 10 to 35dB in 5dB steps Frequencies presented sequentially: 1000, 2000, 3000, 4000 Hz.
  • Easy to read displays, quiet soft membrane switches to facilitate testing.
  • Portable package with padded bag, weighs 5 lbs.
1000+ AMBCO Digital Audiometer 1000 + OTO-SCREEN (no Printer port) $1,038.00 Call to Order
1000+PNP AMBCO Digital Audiometer 1000 + OTO-SCREEN has port without printer $1,315.00 Call to Order
1000+P AMBCO Digital Audiometer 1000 + OTO-SCREEN with the DPU-S445 Thermal Printer & paper $1,690.00 Call to Order


Model 2500
audiometer 2500 + OTO-CHEK




Model 2500P
audiometer 2500 + OTO-CHEK




Model 2500PKG
audiometer 2500 + OTO-CHEK

AMBCO Automatic microprocessor controlled audiometer 2500
Ideally suited for industrial, occupational health, physicians and clinics that need to meet O.S.H.A. hearing test requirements.

FEATURES
  • Automatic, semiautomatic, manual tests
  • Internal memory stores up to 260 tests
  • Computer compatible
  • Large character Lcd display
  • Monitor test conditions in process
  • Input social security number for ID
  • Calibration date, test date, calibration due date on report
  • Visual and audible alarms
  • Pause, resume for operator control
  • WARRANTY: 5 years on base system
PRINTER FEATURES
  • Print and store tests automatically
  • Large print out results
SPECIFICATIONS:
  • MEETS OR EXCEEDS A.N.S.I. S3.6-1989, O.S.H.A. REQUIREMENTS
  • TEST FREQUENCIES: Accuracy better than 1% AUTOMATIC: 500, 1000, 2000, 3000, 4000, 6000, 8000 (with validity check at 1000 Hz) SEMIAUTOMATIC & MANUAL MODES: 250. 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 (Hz)
  • TOTAL HARMONIC DISTORTION: Less than 3%, typical 1%
  • HEARING LEVEL RANGE: 0 to 95dB in 5dB increments except at 125Hz to 75dB and 250 and 8000 Hz to 85dB. Accuracy +/- 1dB
  • DATA OUTPUT: RS-232 9600 baud, 8 bits, no parity, DTR for printer/computer ID
  • STORAGE CAPACITY: Up to 260 Audiograms
  • EARPHONES: TDH-39, 10 Ohm
  • DISPLAY: .375 high, 2 line by 16 characters, backlight LCD
  • POWER SUPPLY: 107-127 VAC 60 Hz, 10 Watts. UL Approved (optional 220 VAC 50/60 Hz available)
  • CASE: Impact resistant A.B.S. plastic, W 10" x L 8" x H 4.2". Total audiometer weight 4.0 Ibs.
2500 AMBCO Automatic microprocessor controlled audiometer $2,556.00 Call to Order
2500P AMBCO Automatic microprocessor controlled audiometer with the DPU-S445 Thermal Printer & paper $3,023.00 Call to Order
2500PKG AMBCO Automatic microprocessor controlled audiometer + OTO-CHEK with the DPU-414 Thermal Printer & paper $3,342.00 Call to Order



OTO-CHEK Biological Test Simulator
OTO-CHEK Biological Test Simulator
Ambco, Biological Test Simulator. OTO-CHEK can be used with any manual audiometer or automatics with normally open relay contacts. Meets OSHA and other requirements for Biological Audiometer Calibration Checks. SPECIFICATIONS
  • TEST FREQUENCIES: Full range 125 to 8K Hz.
  • STIMULUS FORMAT: Continuous or pulsed.
  • POWER SOURCE: AC Adapter (output 14V DC 220mA) or 9 Volt battery.
  • WEIGHT: Less than 2 pounds.
  • RESPONSE OUTPUT: Normally open relay contacts.
  • WARRANTY: 5 years on base system
MEETS OSHA AND OTHER REQUIREMENTS FOR BIOLOGICAL AUDIOMETER CALIBRATION CHECKS.